PAGE 6
Using an entry conrmation button
Where two door readers may pick up the same hands free token, a push to make button can be used to conrm
an entry request for the specic door. Where tted, the button LED will ash for 5 seconds after the hands free
token has been recognised and must be pressed to unlock the door.
To enable the use of an entry conrmation button do the following steps:
1. Power down the interface board
2. Power up the interface board
3. Press and hold the entry conrmation button for a minumum of 3 seconds within 60 seconds of power up.
To disable the use of the button repeat the above process.
11V DC 14V DC
1 A
119 kHz 140 kHz
2.405 GHz 2.480 GHz
600 µs
Belden 9540
100 yds
3 inch 1
1
/2 inch
1
/2 inch
16 ft
6 ft
P200 8 ft
P75 5 ft
P50 4 ft
P38 3 ft
-35°C (-31°F) +66°C (+151°F)
IP66
8
1
/2 inch 8
1
/2 inch 4
3
/4 inch
Specications
Voltage
Clock and data bit period
Carrier frequency
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height Depth
Current
P200E metal mount
Cable type for extensions
Cable length between ACU and reader
Read range with hands free token
System Specication
Waterproof
Additional power supply required
Outdoor Use
Button conrmation input
Yes
Yes
Long range reader
Min
Min
Min
Max
Max
Max
Token
Keyfob
Watchprox
Read Range
Long range reader
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Changes or modications not
expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.