Paxton Access Ltd hereby declares that this product is in conformity with all the essential requirements of Directive
1999/5/EC. This equipment is intended for use in all EU and EFTA countries and all other countries worldwide.
10V DC
14V DC
130 mA
115 kHz 135 kHz
-35 °C
+66 °C
IPX7
45 mm 100 mm
20 mm
85 mm
Voltage
Carrier frequency
Specications
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Width
Height
Depth
Current
Cable length
Read Range
Token
Hands Free Token
Waterproof
Min
Max
Wiring
Connection to a Net2
ACU reader port
+12V DC
Red LED
Amber LED
Green LED
Clock/data1
Data/data0
Not required
0V
Token type and conguration
The reader will recognise 125 kHz HID
TM
proximity tokens in format to produce a Wiegand output (26 to 50 bit) or
EM4100 tokens to produce a Clock and Data output.
The reader scans the rst token presented after power up and will match the reader mode to the format discovered.
If no token is read within 3 minutes of powering up, the reader will default to HID
TM
. If you require EM4100
operation, power cycle the reader and present an EM4100 token within 3 minutes.
Once in HID
TM
or EM4100 mode, the reader will remain in that format.
The declaration of conformity is available on request. Contact details are provided at: http://paxton.info/596
Not Compatible
If used with Net2, the ACU reader port must be congured to read the correct data format.
Where Wiegand cards are used, you must set the correct data format (e.g. Wiegand 26 bits) in the ACU
reader port conguration or create a custom wiegand lter in the Net2 Server Conguration Utility. For further
information see: AN1010 - Conguring custom Wiegand formats < http://paxton.info/990 >